Myriad Dual-Phase Power Converter Installation Guide (MPN2805)
Overview
The Myriad Dual-Phase Power Converter (MPN2805) is designed to provide a stable 12V DC power output from two-phase AC input systems used in high-performance industrial and transport refrigeration environments.
Engineered for reliability and efficiency, the converter supports high-voltage input ranges and integrates battery monitoring and surge protection to ensure stable operation of connected electrical components.
This bulletin provides an overview of the converter specifications, installation requirements, and electrical connection guidelines.
Key Features and Performance
The Myriad Dual-Phase Power Converter offers reliable power conversion for demanding electrical systems.
Electrical Performance
-
Input voltage: 340–640V AC (two-phase input)
-
Output voltage: 12V DC
-
Maximum power output: 280W
-
Maximum output current: 20A at 14V DC
These specifications allow the converter to provide stable power for electrical control components and other low-voltage devices.
Converter Design and Dimensions
The converter is built for durability and easy installation within industrial and transport refrigeration environments.
Physical dimensions
-
Length: 242 mm
-
Width: 208 mm
-
Height: 133 mm
Mounting
The converter includes four oblong mounting points (10 × 20 mm) for secure installation.
Grounding
An M8 grounding stud is provided to ensure safe and reliable grounding during installation.
Electrical Connections
The converter uses dedicated connectors to ensure secure and stable electrical connections.
Input Connector
-
Amphenol AT04-3P-SR01BLK or equivalent connector
Output Power Connection
-
Standard M8 terminals used for power output distribution
Technicians should verify that all wiring connections are properly secured before powering the system.
Battery Temperature Monitoring
The converter includes an integrated battery temperature sensor designed to monitor battery conditions during operation.
This feature helps protect the battery system and ensures efficient power management, improving overall battery longevity.
Surge Protection Requirement
For safe system operation, the converter requires external circuit protection.
Install either:
-
4A time-delay fuse, or
-
4A circuit breaker
This protection helps prevent electrical damage caused by surge conditions or overload.
Two-Phase System Configuration
The power converter is designed for two-phase AC systems.
The converter does not require a specific phase order, allowing flexible installation within compatible systems.
This simplifies installation in industrial and high-demand environments where phase orientation may vary.
Download the Full Technical Bulletin
For the complete technical specifications and installation guidance, download the original bulletin.
Download PDF Technical Bulletin